Reduce the price and size of the vacuum hardware.
microIOC-LOCO2 is a high-voltage power supply stand alone unit that can distribute power to up to 16 ion-pumps. Varian Dual Controller is used as a power supply and microIOC-LOCO as the distribution system. To enable direct integration into the control system microIOC is integrated into the unit. The unit can be controlled also locally using an LCD located on the front panel.
In addition to providing power to the pumps, current going through every pump is measured and pressure at the pump is determined. If the measured pressure is outside the desired limits, interlocks can be triggered to avoid pump damage. Every pump can be disconnected separately.
microIOC-LOCO2 is an ideal solution to cut costs and rack space by at least a factor of 2 of vacuum systems where a large number of smaller pumps are used, such as storage rings and boosters.
It is a preferred solution over microIOC-LOCO when single pump disconnection is desired or when integration wants to be avoided.
In addition to providing power to the pumps, current going through every pump is measured and pressure at the pump is determined. If the measured pressure is outside the desired limits, interlocks can be triggered to avoid pump damage. Every pump can be disconnected separately.
microIOC-LOCO2 is an ideal solution to cut costs and rack space by at least a factor of 2 of vacuum systems where a large number of smaller pumps are used, such as storage rings and boosters.
It is a preferred solution over microIOC-LOCO when single pump disconnection is desired or when integration wants to be avoided.
Key features
- Plug&Play solution: CS running on a microIOC. EDM, WebCA and java GUIs. LCD for local control.
- Integrated Varian DUAL controller.
- Pressure range from 10(-12) mbar to 10(-4) mbar (current vs. pressure relation is fully configurable)
- Individual pump disconnection. (manual or automatic)
- Safety interlock feature for cable disconnection.
- Very fast double mode over-current protection against electrostatic discharges.
- RS485 serial communication.
- Several customization options.
Benefits
- Reduces cost and rack space: if one pump is connected per controller channel the price per pump is around 2000 EUR and 2U of rack space is used. Depending on the vacuum system these values can drop to 300 EUR and 0.4 U when LOCO 2 is used.
- Pressure measurements at each pump allow problem pinpointing.
- Ion pump protection: in case of poor vacuum any individual pump is automatically switched OFF
- Control over the number of active pumps
| microIOC LOCO2 | |
| high-voltage outputs for the ion pumps | |
| voltage | 2x ±3,000 V to ±7,000 V, programmable |
| number of output channels | 2x8 (1x16 or smaller number of channels available on request) |
| allowable output current | 2x 400mA |
| allowable output power | 420W max |
| output high-voltage connector | Fischer D105A049 with interlock (other type on request) |
| high voltage output current measurement / channel | |
| input-to-output voltage drop | 14V max (Iout < 140mA) / 5V max (Iout > 140mA) |
| current measurement range | 100pA – 10mA |
| normal range of operation | 400mA |
| current measurement principle | measured and integrated over 1 and 10s interval (other intervals on request) |
| current accuracy | guaranteed: ± 10%, typically: ± 5% |
| high voltage output channel ON/OFF switching / channel | |
| switching method | when needed that any of the switches should change a state (opened or closed) firstly request to HV power supply sends to switch OFF output voltage and then switches state changes would be done |
| switching time | max 5s for the whole switching procedure: waiting that output voltage falling under 50V, changes states on switches, rising output voltage to final value |
| communication and control option | |
| RS485 – Varian DUAL | RS 485 multi-drop, single wire, ASCII protocol |
| RS485 – LOCO 2 | RS 485 |
| Ethernet - optional | direct Ethernet CS access: integrated x86 compatible GEODE GX800 CPU, 10/100 Ethernet, 2x USB, RS232, VGA installed SW: Linux Debian, full control system integration (EPICS/EDM, ACS, Tango) |
| Front panel LCD - optional | direct local control with 6,5” LCD, 640x480 resolution, touch screen, EDM SW installed |
| case, mains supply, operating environment | |
| dimensions of enclosure | 19" 6U rack mountable enclosure (265 x 430 x 435mm) |
| weight | 20.5 Kg (45.0 lbs) |
| mains supply | 100-120 / 200-240 VAC, 50/60 Hz, 675VA max. |
| environment | operating: 0…+40°C, storing: -20…+60 °C, operating humidity: 10…90% (non condensing) |
LOCO2 module